2-10 Radical-7 Color Display Signal Extraction Pulse Oximeter Operator’s Manual Radical-7 Color Display Signal Extraction Pulse Oximeter Operator’s Manual 2-11
system description
2
SYMBOLS
The following symbols are found on the back of the Radical-7 Pulse CO-Oximeter Docking
Station or packaging and are defined below:
NOTE:
Some of the interfaces and symbols are not available in all versions of the
Docking Station.
SYMBOLS DEFINITION
RS-232
SatShare Interface
Equipotential Ground Terminal
See Instructions for Use
Fuse Replacement
Analog Out Interface
Nurse Call Interface
WEEE Compliant
Mark of Conformity to European Medical Device Directive
93/42/EEC
Rx ONLY
Federal law restricts this device to sale by or on the order of a
physician (USA audiences only)
Underwriter's Laboratories Inc. approved
5%-95% RH
Storage humidity range: 5% to 95%
-40 C
+70 C
+1060 hPa - +500 hPa
95 mmHg - 375 mmHg
Storage temperature range: +70˚C to -40˚C
Storage altitude range: +1600hPa to +500hPa
Keep dry
Fragile/breakable, handle with care
system description
2
STANDALONE BACK PANEL
1
SERIAL OUTPUT
CONNECTOR
Use the Serial Output Connector with a ferrite bead installed
to connect a serial device, including a serial printer, RadNet
Interface Module or PC, to the Radical-7 Pulse CO-Oximeter.
The data is provided in standard RS-232C format. See
Section 7, Serial Interface Specifications. All external
device connections to the Serial Output Connector must be
IEC-60950 compliant.
2
ANALOG OUTPUT
/ NURSE CALL
CONNECTOR
Use the Analog Output Connector with a ferrite bead installed
to interface with an analog output device, such as a chart
recorder or nurse call system. All external device connections
to the Analog Output / Nurse Call Connector must be IEC-
60950 compliant.
3
SATSHARE CABLE
CONNECTOR
Use the SatShare Cable Connector to connect a SatShare cable
to the SpO
2
input connector of a multiparameter patient monitor.
All external device connections to the SatShare Cable Connector
must be IEC-60601-1-1 compliant. SatShare cables are available to
interface with most major multiparameter patient monitors. Check the
label on the SatShare cable and the SatShare Directions for Use to
ensure that the correct cable is used for each type of patient monitor.
Refer to Section 10 - Accessories of this manual or the Masimo web
site at www.masimo.com for the latest SatShare cables and validated
instruments.
4
POWER ENTRY
MODULE
The power entry module contains the input connector for AC
power and two fuses. The AC input provides power to the sys-
tem from the AC line. Always connect the Pulse CO-Oximeter
to the mains power for continuous operation and/or battery
recharging.
NOTE: Use the power cord as the means to disconnect the
device from the mains power supply.
5
EQUIPOTENTIAL
GROUND
CONNECTOR
Use the Equipotential Ground Connector for grounding.
1
2
3
5 4
P2 P3
Manufactured by:
Masimo Corporation
Irvine, CA 92618 USA
Made in USA
Rx Only
Covered by one or more of the following U.S. Patents: RE38,492, RE38,476,
6,850,787, 6,826,419, 6,816,741, 6,699,194, 6,684,090, 6,658,276, 6,654,624,
6,650,917, 6,643,530, 6,606,511, 6,584,336, 6,501,975, 6,463,311, 6,430,525,
6,360,114, 6,263,222, 6,236,872, 6,229,856, 6,206,830, 6,157,850, 6,067,462,
6,011,986, 6,002,952, 5,919,134, 5,823,950, 5,769,785, 5,758,644, 5,685,299,
5,632,272, 5,490,505, 5,482,036, international equivalents, or one or more of the
patents referenced at www.masimo.com/patents. Products containing Satshare®
P1P1
MEDICAL ELECTRICAL EQUIPMENT
UL 60601-1/CAN/CSA C22.2 No. 601.1
80FK
Komentarze do niniejszej Instrukcji